Software Changes

Change log from firmware version to version.

Firmware

Changes made from version to version

ver_281 - 283 optimising interface between PC and Controller, added Speed Fail reset from PC.

ver_280 menu now 5 lines, a lot of changes to be compatible with new HTML Tool

ver_273 Now also Live data works in both 20 and 50 mS

ver_272 Works now for new HTML parameter tool

ver_271 same

ver_270 Start to test an new HTML program

ver_269 delay on shift for MaxxECU

ver_268 Total km to MaxxECU

ver 267 Some Porsche Tiptronic test

ver 266 Can backup EEPROM

ver_265 More MAxxECU

ver_264 MaxxEcu, Also Receive data from MaxxECU, Speed, RPM, TPS, MAP,

ver_264

extendedMessage20(); byte data[] = { ShiftCut , downshift_maxxecu, GearLever, W_S, manual, 00, 00, 00};

extendedMessage21(); byte data[] = { VSSGear , GearboxMode, GearOilTemp, oilpressure_MaxxECU, Map_MaxxECU, TPS, RPM_MaxxECU, Speed};

ver_263 MaxxECU Even More data over CANBUS, See MAxxECU under userguide

ver_262 MaxxECU more data over CANBUS,

ver_261 solved that Lockup happened to Early and did not worked correct with external RPM

ver_260 Solved shift with locked converter

ver_259 Some CANBUS issue fixed

ver_258 IF external RPM is used lockup did not worked is now solved

ver_257 VNT relaIFted

ver_256 RPM added to MaxxECU byte data[] = { VSSGear , GearboxMode, GearOilTemp, 00, 00, 00, RPM_MaxxECU, Speed};

ver_255

Speed added to MAXXECU byte data[] = { VSSGear , GearboxMode, GearOilTemp, 00, 00, 00, 00, Speed};

ver_254

Alot of changes, better CANBUS support,

Canbus has now its own setup menu in the Setup Parameter›CANBUS NEW where you choose what to activare

ver_239

Fixe issue CANBUS filtering again ;-)

ver_238

Fixes issue with CANBUS filter when running DSL-1 latest version

ver_237

CANBUS issue

ver_236

CANBUS issue

ver_235

Now able to se this message out on CANBUS { Speed, outputValue, GearLever, ActualGear, W_S, manual, GearOilTemp, Volt };

ver_234

Can send out W210 cluster Speed and RPM and at the same time use Tiptronic shifter

ver_233

Now both RPM and Speed is send to CANBUS W210 instrument

ver_232

Slipping lockup if external RPM sensor and set to soft lockup

ver_230

Send out Speed on CANBUS to W210 Display

ver_229

Simple display mode if "Start up Display" is set to 6

ver_228

CAN DSL-1 Update

ver_227

Make sure that lockup over switch is working

ver_226

Make sure the locked converter if RPM engine is lower then 1000 RPM

Ver_223
Reverse block repaired

ver_222

Bugfix for the AUX-2 if used to block movment to R when driving faster than 10 km/h

ver_221

Make sure the spedo shuts totally down if speed is 0 km/h

ver_220

AUX-2 can be used to drive reverse light (tiptronic shifter do not have switch for reverse light)

ver_219

Total revork of the Lockup menu,

ver_218

Added Total reset to Userdata/Factory

ver_217

Added support for TIPTRONIC shifter (PP202267054)

ver_214

Added support for 10 bar Oilpressure sensor on Analog input (0) need wire direct to PCB

ver_213

Chrysler tiptronic now supported

ver_212

Filter on Boost and EGP new

ver_211

Change to vacuum load

ver_210

Support for vacuum based load if boost part: = -1

ver_209

More changes to support 5 bar map

ver_208

Dyno page

ver_207

Support higher boost 5 bar sensor, some changes

ver_206

Support higher boost 5 bar sensor

ver_205

Problem that it relased solenoid in N and it was ableto move it to R at speed.

Ver_204

Special Lockup if "Lockup 2-4" is set to 12 then lockup only if TPS>80% in gear 3, 4 and 5

min speeds: 3gear 100km/h, 4gear 125km/h, 5gear 150km/h

Ver_203

Ver_202

IF Mercedes Gear Lever is not used it now makes sure it start in Auto mode, if it is set to start in Auto

Ver_201

If using DSL-1 you can now adjust at what Rack position should give 100% Load.

LOAD = (CAN_rackpos * 40) / "Boost Part load"

IF you set "Boost Part load" = 40 then it behave same as in previus version

IF you set "Boost Part load" = 20 then you have Full Load = max hard shift at 50% Racktravel,

ver_200

Special lockup for a customerif "Lockup 2-4 gear" is set to 11 then it lock converter if (Speed > 25 & TPS > 20 & boost > 0.5 bar )

ver_199

Future initialication of the Display

Also FIX the problem that sometime controller started in Manual, So when gearlever is put in drive it goes in Auto, if it is set to do that.

ver_198

CANBUS send's Speed / Actual Gear / Gear Lever position back to DSL-1 (Baldur OM606 controller)

ver_197

Some testing.

ver_194 / ver_195 / ver_196

If you go to manual with the joystick, paddle now also work in here.

An extra menu is added in the TPS menu to choose Agressiv TPS profile (Use with Diesel Mekkan pump)

ver_193

Tiptronic shifter supported

ver_192

Tiptronic beta not released

ver_191

Canbus problem fixed when using DSL-1 with more than 2,5 bar boost

ver_190

Small fix BETA

ver_189

Small fix BETA

ver_188

Default now load "Fail Handling" to 1 before 2

ver_187

Joystick problem

ver_186

Baldur DSL1 parametre. CANBUS fix

ver_185

Allow shift with low TPS

ver_184

More Easy reset after shut down under speed. but still safe

Auto detect gear Lever, if it is set to Mercedes GearLever and that is not connected it's automatic switch to No GearLever }

ver_183

Temp min max is put in to test for easy fail search

ver_182

Fail mesagges

ver_181_01

extra setting for external speed

ver_180

Special lockup for racing mode

Shift firmness depending on voltage

Graphics speedo, press up on joystick when in gearindicator mode, or set start up display to 4

ver_179

EEPROM thing (Internal)

ver_178

EEPROM thing (only factory relevant)

ver_177

EEPROM (only factory relevant)

ver_176

Only OLED display